2.12.8 Asynchronous motors optimisation
CONFIGURATION ► FREQ. INVERTER ► ASYNC. OPTIMIZ.
Press « ENTER » to go in the menu
Réglage du courant magnétisant du moteur à basse vitesse
Press « ENTER » to go in the menu
2.12.8.1 Slip compensation
CONFIGURATION ► FREQ. INVERTER ► ASYNC. OPTIMIZ. ► SLIP
This parameter can increase the stop precision and the comfort of the travelling
Adjusts the slip compensation around the value set by the rated motor speed.
The speeds given on motor nameplates are not necessarily exact.
• If slip setting < actual slip: the motor is not rotating at the correct speed in steady
state, but at a speed lower than the reference.
• If slip setting > actual slip: The motor is overcompensated and the speed is
unstable.