USER MANUAL « ASP 116 EVOLUTION »
Sprinte SAS, All rights reserved, including translation rights
It is necessary to indicate the use of a retractable toe-guard as safety is deactivated by
a cam on the lowest level (connector DETECT 1m 210SP board). The control panel
must check that the cam returns correctly to normal position once the car has exited
the area.
Access code with the car buttons to reserve an access to a floor.
Levels can be protected by a code entered using the button box cab. Ten levels can be
protected and it is possible to choose which side door is secure. The access code is 4
digits.
ACCES 1…ACCES 10 DOOR [1..2]
Access code Schedule of the protected floors
The access codes may be active night and day or only part of the day or by activation
of an external input
[DAY ONLY] [NIGHT ONLY] [NIGHT AND DAY] [EXTERNAL INPUT]
Access code of the building
Protection of all the floors by a unique code.
Access code schedule of the building
The access code may be active night and day or only part of the day or by activation
of an external input
[DAY ONLY] [NIGHT ONLY] [NIGHT AND DAY] [EXTERNAL INPUT]
Timer to re-enable car call
A disabled car call (via input BLOCK CAR) will be re-enabled during this delay once
the matching input « UNBLCK CAR » is activated.