MANUEL D’UTILISATION « ASP 116 EVOLUTION »
Sprinte SAS, All rights reserved, including translation rights
and A3 Brake Control
configured)
the maintained out of order mode of the lift (fault erasement in the diagnosis
menu needed).
See installation manual for full description of this test.
Skidding fault detection test.
This test moves the car in slow speed, ignoring all information’s datas from the sahft
reader.
Once the « NO CAR MOVEMENT » timer (see §2.10.2) has elapsed, the
« SKIDDING » fault must have been detected and recorded.
See installation manual for full description of this test.
Levelling functionality test
This test moves the car with the doors opened, then you can check the automatic
relevelling of the lift.
See installation manual for full description of this test.
Launch a software upgrade for a distant board
Use this function, if there is a « VERS. BOARD » in the controller’s fault list, in case
you have replaced a distant board (211SP or 230SP in car, or 228SP, 137SP on
floors), in order to upgrade the software according to the one of the controller.
Displays absolute reader (K04SP/K05SP) information
- speed, altitude, precision stopping, direction of travel
Updates the date of the last maintenance visit
Selecting “YES”, the date of the last maintenance visit is updated to the current date
of the controller. This date will be displayed on the 236SP color display in car if you
have selected the option (see §2.19.1).
Displays the date of the last maintenance visit