78 Netra T2000 Server Installation Guide • September 2006
▼ To Power On the Server for the First Time
1. If you have not already done so, connect a terminal or a terminal emulator (PC or
workstation) to the SC serial management port.
Configure the terminal or terminal emulator with these settings:
■ 9600 baud
■ 8 bits
■ No parity
■ 1 Stop bit
■ No handshaking
Note – When you power on the server for the first time and you do not have a
terminal or terminal emulator (PC or workstation) connected to the SC serial
management port, you will not see system messages. The display disappears after
about 60 seconds.
2. Turn on the terminal or terminal emulator, if it is not already turned on.
3. Connect the input power cables to Power Supply 0 and Power Supply 1, and
watch the terminal for system messages.
FIGURE 6-1 Rear Panel Power Connectors
After the system controller boots, the system controller login prompt is displayed on
the serial console. The following example shows partial output from the system
controller boot sequence leading to the login prompt.
CODE EXAMPLE 6-1 Sample System Controller Output
ALOM POST 1.0
Dual Port Memory Test, PASSED.
Power supply 0 Power supply 1