EasyManua.ls Logo

Sun Microsystems SPARCstation 5 - Environmental Requirements

Sun Microsystems SPARCstation 5
210 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Specifications A-3
A
A.3 Environmental Requirements
Table A-3 lists the environmental requirements for both operating and
non-operating environments.
Table A-3 Environmental Requirements
Operating Environment:
Temperature range 0 ˚C to 40 ˚C (32 ˚F to 104 ˚F) at 20%–70% Relative
Humidity (RH), noncondensing—IEC 68-2-1, 68-2-2
Humidity 5% to 95% RH, noncondensing—IEC 68-2-2, 68-2-3
Altitude range 0 to 3000 meters (0 to 9840 feet), 10 ˚C to 40 ˚C (50 ˚F to
104˚F)—IEC 68-2-40, 68-2-41
Vibration 0.25 gravity (g) peak, 5–500 Hz, 3 perpendicular axes—
IEC 68-2-6
Shock 5 g peak, 11 milliseconds half-sine pulse—IEC 68-2-27
Non-Operating Environment:
Temperature range -40 ˚C to 75 ˚C (-40 ˚F to 167 ˚F) at 20%–70% RH,
noncondensing—IEC 68-2-1, 68-2-2
Humidity 95% RH, noncondensing—IEC 68-2-2, 68-2-3
Vibration 1 g peak, 5–500 Hz, 3 perpendicular axes—IEC 68-2-6
Shock 30 g peak, 11 milliseconds half-sine pulse—
IEC 68-2-27e

Table of Contents

Related product manuals