MAINTENANCE AND TUNE-UP PROCEDURES
This section describes the servicing procedures for each item
mentioned
in
the Periodic Maintenance chart.
AIR CLEANER
I Clean
every
3
months
.
If the air cleaner is clogged with dust, intake resistance will be
increased. with a resultant decrease
in
power output and an
increase in fuel consumption. Check and clean the air cleaner
element in the following manner.
Remove the seat.
Remove the air cleaner case cover
(1).
Remove the air cleaner element
~.
Separate the polyurethane foam element @. element frame
@ and element holder.
Fill a wash pan of a proper size with a non·flammable clean-
ing solvent. Immerse the air cleaner element in the cleaning
solvent and wash
it.
Press the air cleaner element between the palms of both
hands to remove the excess
solvent
do not twist or wring the
element or it will
tear_
Immerse the element in motor oil, and then squeeze oul the
excess
oil leaving the element slightly wet.
® Non-flammable cleaning solvent
@ Motor oil SAE
130