CAMSHAFT
JOURNAL
WEAR
Measure
the
oil clearance, with the camshaft instaHed, using
the
plastigauge.
,
,'8&
109900-22301:
Plastlgauge
09900-22302:
Plastigauge
_
Camshaft
Journal
all
clearance (IN &
EX
)
Service
Limit
: 0.
150
mm
(0.0059 In)
•
Tighten the camshaft journal holder bolts evenly and
in
diago-
nal stages to the specified
to
rque.
~
Camshaft
journal
holder
bolt
:
10
N·m
(1
.0
kgf
-m,
7.0
Ib-It)
NOTE:
Do
not
rotate the camshaft with the plastigauge in place.
Remove the journal holders and read
the
width of the com-
pressed plastigauge with the envelope scal
e.
This measurement
should
be
taken al the widest part of the compressed plasti-
gauge.
If the camshaft journal oil clearance exceeds the seNiee limit,
measure the inside diameter of the
camshaft
journal holder
and
outside diameter of the camshaft journal. Replace the camshaft
or the
cylinder head and camshaft hol
der
depending upon which
one exceeds the specification.
eJ
09900-22403:
Small
bore
gauge
_
Camshaft
journal
holder
1.0. (IN & EX)
Standard
: 22.
012
-
22
.025
mm
(0.8666 - 0.8671
in
)
n
'O&
! 09900-20205:
Micromete
r (0 - 25
mm)
_
Camshaft
journal
0 .0 . (IN & EX)
Standard:
21
.972 -
21
.993
mm
(0.8653 - 0.8659
in)
CAMSHAFT
RUNOUT
Support
the
valve using V-blocks and
measure
the
camshaft
runout using the dial gauge. If
the
runout exceeds
the
service
limit, replace the camshaft with a
new
one.
,
,'8&
109900
-20606: Dial
gauge
(11100
mm)
09900-20701: Magnetic
stand
09900-21304: V-
block
set (100
mm
)
_ Camshaft run
out
Service
Lim
i
t:
0.10
mm
(0
.004 in)
EN
G
INE
3-29