7-16 ELECTRICAL SYSTEM
Measure the relay coil resistance between the terminals using
the multi circuit tester. If the resistance is not within the specified
value, replace the starter relay with a new one.
# 09900-25008: Multi circuit tester set
) Tester knob indication: Resistance (Ω
ΩΩ
Ω)
& Starter relay resistance
Standard: 3 – 6 Ω
ΩΩ