6 – Modules
Dynamics parameters
NOTE
Turn the LCD knobs to adjust them. They can also be adjusted
by dragging the green and blue and icons on the graph.
GATE
Parameter name Range default
THRESHOLD -80 dB – 0 dB -25 dB
RANGE -60 dB – 0 dB -50 dB
ATTACK 0 ms – 125 ms 0 ms
HOLD 0 ms – 990 ms 20 ms
DECAY 5 ms – 5.00 s 300 ms
EXPANDER
Parameter name Range default
THRESHOLD -60 dB – 0 dB -40 dB
RATIO
1:1, 2:1, 4:1, 8:1, 16:1, 32:1,
64:1
4:1
KNEE HARD, MID, SOFT MID
ATTACK 0 ms – 125 ms 10 ms
RELEASE 5 ms – 5.00 s 250 ms
DE-ESSER
Parameter name Range default
THRESHOLD -40 dB – 0 dB -15 dB
KNEE HARD, MID, SOFT MID
CENTER FREQ 1.0 kHz – 10 kHz 4.0 kHz
Q 1.04 – 17.31 17.31
NOTE
The peak position of this DE-ESSER EQ graph shows the
maximum gain reduction amount. Moreover, this DE-ESSER
operates at a 2:1 ratio.
For this reason, the peak position range of the EQ graph is -20
dB – 0 dB , which is half the Threshold range of -40 dB – 0 dB.
TASCAM Sonicview 16/Sonicview 24 V1.1.0 133