4-45
5) 03-11=4. RY will be on as soon as the Output frequency > Preset frequency reached level (03-13)
6) 03-11=5. RY will be on as soon as the Output frequency < Preset frequency reached level (03-13)
7) 03-11/03-12=20Zero Speed
Off Output Frequency => Minimum Frequency (01-08,Fmin)
On Output Frequency < Minimum Frequency (01-08,Fmin)
01-08Fmin
Output
Frequency
Zero
Speed
OFF
ON
t
t