EasyManua.ls Logo

TECO e510 series - Application Instructions; Counter

TECO e510 series
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4- 83
4.4.3 Application Instructions
1. Counter
Symbol Description
Counting Mode (1-4)
Use (I1 ~ f8) to set counting up or
counting down
OFF:counting up (0, 1, 2, 3, 4….)
ON :counting down ( ….3, 2, 1, 0)
Use (I1 ~ F8) to RESET the
counting value
ON :the counter is initialized to zero
andOFF
OFF: the counter continues to
count
Present Counting Value
Target (Setting)
Value(AS1~AS4,MD1~MD4,T1~T8,C
1~C8,V1~V7,count)(0~65535)
Code of the counter (C1 ~ C4 total:
4 groups).
Mode 1:
The count value is locked to the set valueOff electricity didn't keep
Mode 2:
Count value unlockedOff electricity didn't keep
Mode 3:
Count value lockedOff electricity keep
Mode 4:
Count value unlockedOff electricity keep
(1) Counter Mode 1
1
ON
OFF
=1
5
4
00011221 1 0 1919202020 0 2020
20
Input count pulse
2
3
6
OFF
ON
ON
ON
OFF
OFF
OFFON
ON
1
4
5
2
3 6