4-24
Group 12 Digital Display & Monitor Functions
No. Description Range
Factory
Setting
Unit Note
12-00
Extended Display Mode
00000~88888
Each digit can be set from 0 to 8 as
listed below.
00000 - *1
0: Default Display
(Frequency and Parameters)
1:Output Current
2:Output Voltage
3:DC Voltage
4:Temperature
5:PID Feedback
6:Analog Signal Input. (AI1)
7:Analog Signal Input. (AI2)
8:Count Status
12-01
PID Feedback Display Format
0:Integer (xxx)
0 - *1
1:One Decimal Place (xx.x)
2:Two Decimal Places (x.xx)
12-02
PID Feedback Display Unit
Setting
0:xxx--
0 - *1
1:xxxpb(pressure)
2:xxxfl(flow)
12-03
Custom Units (Line Speed)
Value
0~65535 1500/1800 RPM *1
12-04
Custom Units (Line Speed)
Display Mode
0:Drive Output Frequency is Displayed
0 - *1
1:Line Speed.Integer.(xxxxx)
2:Line Speed.One Decimal Place.
(xxxx.x)
3:Line Speed.Two Decimal Places
(xxx.xx)
4:Line Speed.Three Decimal Places
(xx.xxx)
12-05
Inputs and Output
Logic Status Display
( S1~S6, RY1 and RY2)
S1 S2 S3 S4 S5 S6
RY1
RY2
PLC
- - *4
12-06
Alarm Selections for Inverter
Components Life Expectancy
xxxx0:Life Alarm of Inrush Current
Suppression Circuit is Invalid
xxxx1:Life Alarm of Inrush Current
Suppression Circuit is Valid
00000 - *1
xxx0x:Life Alarm of Control Circuit
Capacitors is Invalid
xxx1x:Life Alarm of Control Circuit
Capacitors is Valid
xx0xx:Life Alarm of Main Circuit
Capacitors is Invalid
xx1xx:Life Alarm of Main Circuit
Capacitors is Valid