4-47
03-18
03-17
RUN
command
03-11=14
Hz
T
ON
OFF
RUN STOP
03- 19 Relay Output Status Type
Range
0:A (Normally open)
1:B (Normally close)
When 03-19=0,
When the set conditions of 03-11,03-12 are met , relay contact is closed, otherwise it will be open..
When 03-19=1,
When the set conditions of 03-11,03-12 are met ,relay contact will open,Otherwise it will be closed.
03- 20 Internal / External Multi-Function Input Terminal Selection
Range
0~63
03- 21 Action to Set the Internal Multi-Function Input Terminals
Range
0~63
Parameter 03-20 determines if external/ internal control for multi-function inputs S1-S6 is selected.
The corresponding contact is set to 1 when internal multi-tunction input is selected and it is set to 0
when the external one is selected.
The input selection is according to the decimal value set.
DI S6 S5 S4 S3 S2 S1
Binary
5
2
4
2
3
2
2
2
1
2
0
2
Decimal 32 16 8 4 2 1