Group 08- Drive & Motor Protection Functions 
No. Description  Range 
Factory 
Setting 
Unit Note
08-13 
Over Torque Detection 
Control 
0: Over Torque Detection Disabled 
0 -  
1:  Over torque detection after set frequency is 
reached 
2: Over torque detection after run command 
08-14 
Over torque protection 
action 
0: Stop Output After Over Torque Detection 
(Free Run to Stop) 
0 -  
1: Continue Running After Over Torque 
Detection (Display only OL3) 
08-15 
Over Torque Detection 
Level 
30~300 160 -  
08-16 
Over Torque Detection 
Time 
0.0~25.0 0.1 -  
08-17 
Fire Mode (for firmware 
below v1.1) 
0: Disable 
0 -  
1: Enable 
08-18 
Ground Fault Detection 
0: Disable 
0  *7 
1: Enable 
Notes: Regarding fire mode function, please refer to the conditions below, 
1. Below firmware v1.1, Fire Mode is enabled by setting 08-17 = 1 
2. Above (including) firmware v1.1, Fire Mode is enabled by setting digital inputs 03-00~03-05 = 28. 
Parameter 08-17 is then removed. 
3. 08-18 is applicable to frame 3 and 4 only. 
Group 09- Communication function setup 
No. Description  Range 
Factory 
Setting 
Unit Note
09-00 
Assigned Communication 
Station Number 
1 ~ 32  1  -  *2*3 
09-01 
RTU/ASCII Code Selection 
0:RTU Code   
1:ASCII Code 
0 - *2*3 
09-02 
Baud Rate Setting (bps) 
0:4800 
1:9600 
2:19200 
3:38400 
2 bps *2*3 
09-03 
Stop Bit Selection 
0:1 Stop Bit  
1:2 Stop Bits   
0 - *2*3 
09-04 
Parity Selection 
0:Without Parity 
1:With Even Parity 
2:With Odd Parity 
0 - *2*3 
09-05 
Data Format Selection 
0: 8-Bits Data   
1: 7-Bits Data 
0 - *2*3 
09-06 
Communication Time-Out   
Detection Time 
0.0 ~ 25.5 
0.0 Sec    
09-07 
Communication Time Out   
Operation Selection 
0:Deceleration to Stop 
(00-15: Deceleration Time 1) 
1:Coast to Stop 
2:Deceleration to Stop 
(00-17: Deceleration Time 2) 
3:Continue Operating 
0 -    
09-08 
Comm. Fault Tolerance Count.  1 ~ 20 
3         
09-09 
Wait Time of Inverter 
Transmission 
5 ~ 65 
5 ms