3.3.4 Failure liability
Teco bears no responsibility for any failures or damaged caused to the inverter if the recommendations
in this instruction manual have not been followed specifically points listed below,
If a correctly rated Fuse or Circuit breaker has not been installed between the power source and the
inverter.
If a magnetic contactor, a phase capacitor, burst absorber and LC or RC circuits have been connected
between the inverter and the motor.
If an incorrectly rated three-phase squirrel cage induction motor has been used
When one inverter is driving several motors, the total current of all motors running simultaneously must
be less than the rated current of the inverter, and each motor has to be equipped with a correctly rated
thermal overload relay.
“Only Intended For Use In A Pollution Degree 2 Environment” or equivalent.
Since there is no over speed protection there will be no liablity due to overspeed damage.