7-52
Cn089 Regenerative Resistor Resistance Setting
5-6-7
Initial Value Unit Setting Range Effective Cn029 Reset
System setting x0.1 ohm 0 ~ 10000 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
005CH 2059H 2059H O O O O O
Setting description: Please set the resistance value of the regenerative resistor used.
Note) Setting 0 means that regeneration is not used.
Cn090.3 No detection of linear motor encoder Z phase disconnection function
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 1
RS-485 CANopen EtherCAT Pi Pe Pt S T
005DH 205AH 205AH O O O O O
Setting description:
Setting Description
0 Disable the do not detect pulse encoder Z phase disconnection function
1 Enable the do not detect pulse encoder Z phase disconnection function
Cn097.0 Motor disconnection protection flag
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 1 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0064H 2061H 2061H O O O O O
Setting Description:
Cn097.1 EMC stop function selection
5-6-18
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 1 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0064H 2061H 2061H O O O O O
Setting Description
0 Disable motor cable disconnection protection
1
Enable motor cable disconnection protection.
Note: When speed command is 0, it is determined
by position error. Maximum and minimum can be
set by Pn308 & Pn309.