www.ti.com
Output Compare Mode
A compare output pin is initialized to the value listed in Table 9-1 when:
a value is written to T1CNTL (all Timer 1 channels)
0x7 is written to T1CCTLn.CMP (channel n)
Table 9-1. Initial Compare Output Values (Compare Mode)
Initial Compare Output
Compare Mode (T1CCTLn.CMP)
Set output on compare (000) 0
Clear output on compare (001) 1
Toggle output on compare (010) 0
Set output on compare-up, clear on compare down in up-down mode (011) 0
In other modes than up-down mode, set output on compare, clear on 0 (011) 0
Clear output on compare-up, set on compare down in up-down mode (100) 1
In other modes than up-down mode, clear output on compare, set on 0 (100) 1
0
Clear when equal T1CC0, set when equal T1CCn (101)
1
Set when equal T1CC0, clear when equal T1CCn (110)
111
SWRU191CApril 2009Revised January 2012 Timer 1 (16-Bit Timer)
Submit Documentation Feedback
Copyright © 20092012, Texas Instruments Incorporated

Table of Contents

Other manuals for Texas Instruments CC2541EMK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments CC2541EMK and is the answer not in the manual?

Texas Instruments CC2541EMK Specifications

General IconGeneral
BrandTexas Instruments
ModelCC2541EMK
CategoryMicrocontrollers
LanguageEnglish

Related product manuals