Page 6-42 Document Ref 905675-001 Rev 2
Maintenance Modes WWC T1 Set Up & Maintenance Manual
Issue B
6.32.4 KERNEL VERSION < 02.12
Display Explanations/comments
n b b Nozzle Sensor Definition menu.
Press 8 to enter this menu.
oLd
0
0 Replace old sensor number with new sensor number.
r E P 0 0 Select old sensor number:-
The left 0 of the old sensor (oLd) number is flashing.
Press 9 to increase this value.
Press 8 to toggle to right 0. Press 9 to increase this value.
Press 7 to save and continue.
o L d 0 0 Select replacement sensor number:-
rEP
0
0The left 0 of the replacement sensor (rEP) is flashing.
Press 9 to increase this value.
Press 8 to toggle to right 0. Press 9 to increase this value.
Press 0 to exitr nbb menu.
o L d 0 0 When stepping through the possible sensor addresses, the
r E P 0 0 third line will indicate if the selected replacement address is
USEd
detected in the nozzle sensor network.
If USEd is displayed, then the selected address is already in use.
oLd 00
rEP 00 If FrEE is displayed, the selected address is available for use.
FrEE
Press 7 to return to old sensor number and repeat above process.
Press 0 to save and continue.
o L d 0 0 If the selected sensor number is free, the information will be
r E P 0 0 stored and Good will be displayed.
Good
o L d 0 0 If the selected sensor number is invalid, the information will
r E P 0 0 be discarded and err will be displayed indicating an error and the
err
invalid value will be discarded.
Press 0 to exit nbb menu.