Page 6-40 Document Ref 905675-001 Rev 2
Maintenance Modes WWC T1 Set Up & Maintenance Manual
Issue B
6.32.3 KERNEL VERSION >= 02.12
(CONT.)
Display Explanations/comments
n b b Nozzle Sensor Definition menu.
Press 8 to enter this menu.
d I S P L Display Sensor submenu.
S E n S o r All installed sensors are displayed with their specific functions.
Press 8 to enter this submenu.
Press 7 to skip and go to nrext menu (Sensor Activate).
Press 0 to exit nbb menu.
S E n 0 1 The first sensor present is displayed with its function.
r n o 1 If no function is associated with the sensor, no Fun is displayed.
Press 9 to repeat for each installed sensor.
Press 7 to save and continue.
Press 0 to return to nbb menu.
S E n S o r Sensor Activate submenu.
t E S t The current activated sensor will be displayed with its function
as described above.
Press 7 to go to next submenu (Change Sensor).
Press 0 to return to nbb menu.
C H A n G E Change Sensor submenu.
S E n S o r The function of a sensor can be changed in this submenu.
Press 8 to enter this submenu.
Press 7 to go to next menu (Define Sensor).
Press 0 to return to nbb menu.
SEn 01
The first sensor is displayed with its function (top line flashing).
rno1Press 7 to toggle between top line (sensor number) and second
line (sensor function).
Press 9 to display next installed sensor and its function.
Select the sensor to be changed.
Press 7 to change sensor function.
SEn 01 Press 9 to display the next function for the selected sensor.
rno1
Press 7 to toggle between top line (sensor number) and second
line (sensor function).
Change all sensors as required.
Press 0 to continue.