WWC T1 Set Up & Maintenance Manual Application Mode
Document Ref 905675-001 Rev 2 Page 7-3
7.2 EPS
Issue B
Display Explanations/comments
EPS 3 is flashing.
EPS
3
Press 9 to toggle between 3 and 5.
Note : EPS 5 functionality will enable sending of EPS/5
messages to the kiosk; send totals when connected to kiosk;
send lost delivery message in the event of power failure.
Press 7 to save and continue.
Traffic Light menu.
OP T Press 9 to toggle between yes (enable) and no (disable).
no
Press 7 to save and continue.
S U B Sub-Volumes for Blending menu (Belgium only).
voL Press 9 to toggle between yes (enable sending of "H" message
YES
to kiosk for blend transactions to indicate the sub-volumes of
the different grades used) and no (disable).
Press 7 to save and continue.
r o U n d Rounding menu after preset (Italy only).
vALUE t 5 is flashing. Press 9 to set the time (range 1 to 255).
t5
Press 7 to save and continue.
v A P o u r Vapour Mes menu.
nnes If enabled, this will select the protocol extension supporting
no
additional VRC information.
Default no is flashing (standard communication protocol).
Press 9 to toggle to yes (enable VRC extended protocol).
Press 7 to save and continue.