WWC T1 Set Up & Maintenance Manual LPG Set Up
Document Ref 905675-001 Rev 2 Page 3-7
Issue B
3.4.2 TIMING WITH DEADMANS BUTTON ONLY & MOTOR OFF DELAY = 0
motor
valve
Start
LPG Delay
(Deadmans
button)
button
Request
Terminate
Transaction to
kiosk
motor
valve
Start
button
Request
Terminate
LPG Delay
(Deadmans
button)
Transaction to
kiosk
Motor Off
delay = 0
/
3.4 Functionality without Nozzle Switch
3.4.1 TIMING WITH DEADMANS BUTTON ONLY & MOTOR OFF DELAY
0