WWC T1 Set Up & Maintenance Manual Maintenance Modes
Document Ref 905675-001 Rev 2 Page 6-21
Issue B
6.23 Product Relation
This function is required where the product numbers of the Pump Controller are different
to those of the WWC. For example, if the product code for Diesel in the Pump Controller
= 4 then the external product code oUt = 4. If the Diesel product is connected to HCM 1,
then the internal product code In = 1. In this case, the product relation function would set
rIn or LIn = 1 and oUt = 4.
6.22 Emergency Manual Pumping Device (EMPD)
This special function of the WWC enables fuel to be dispensed manually (using handle on
the pump) in the event of a power failure (using a back-up battery) by bypassing the
motor/valves and recording the delivery on the pulser.
Display Explanations/comments
EnnPd EMPD menu.
Press 9 to toggle between yes (enable) and no ( disable).
YES
Press yes to continue with EMPD setting.
Press 8 to enter this function.
Press 0 to exit EMPD.
E n n P d Set the time for the EMPD to run (0 to 45 mins):-
t30Press 9 to increase this value.
YES
Press 7 to save and continue.
Display Explanations/comments
o U t 1 Product Relation menu.
Lower 1 is flashing i.e. internal product 1 on the right (side A)
rIn
1
is selected.
Press 8 to continue.
oUt
1
Upper 1 is flashing i.e. external product 1 on the right (side A)
is selected.
rIn1 Press 9 to increase the value until the required external
product code is reached.
Press 8 to save and continue.
o U t 1 Product Name menu (product name is blank).
-
- is flashing. Enter the product name:-
rIn1 Press 9 to scroll and enter character by character or
Press 3 to select from a pick list