WWC T1 Set Up & Maintenance Manual Maintenance Modes
Document Ref 905675-001 Rev 2 Page 6-29
Issue B
6.30 Product Position
This function assigns the position of Product Indicators, Electro-mechanical Totalisers
(EMT) and Unit Price Displays (UPD) to calculator internal product codes.
For more information, refer to section 2.5.2. Also refer to kernel versions according to
section 6.2 Maintenance Function Overview.
Note: This menu has been removed from the Option Controller Board (OCB) menu because
the EMTs are not controlled via the OCB.
Note : The request to program EMT positions for left hand dispensers means that EMT
connectors are always required for 4/5 products on the Optional Peripheral Board (OPB).
Display Explanations/comments
P r o d 1 Product Position menu.
PoS Prod 1 or the product name (if programmed) is displayed.
r1
r 1 is flashing (right/side A product 1).
Press 9 to select the relevant product position for Prod 1.
Press 8 to go to next product.
P r o d 2 Repeat process until product positions have been set for all
P o S available products.
r2
Press 7 to save and continue.