WWC T1 Set Up & Maintenance Manual Maintenance Modes
Document Ref 905675-001 Rev 2 Page 6-25
Issue B
6.26 Pump Motor Delay (Submerged/Remote pumps only)
This function allows an additional delay to be set (in seconds) for opening the valves after
the pump motor(s) are started.
Note : If enabled, the delay is automatically applied to all pump motors connected to that
dispenser.
6.25 Vapour Delay
This function (implemented since kernel version 3.03) enables extended vapour recovery
error checking and reporting if the parameter >0.
If the VRC system is running in SCG (self calibrating gas) mode and detects a problem in
a hose then the error will be reported to the kiosk. After the vapour delay period expires
(normally 72 hours), the product will be blocked. The VRC status and remaining time per
product will be reported to the kiosk.
Display Explanations/comments
v A P o r Vapour Delay menu.
d E L A Y Set the time delay until hose is blocked (in hours):-
0
0The left 0 is flashing. Press 9 to increase the value.
Press 8 to go to next digit.
v A P o r The right 0 is flashing. Press 9 to increase the value.
dELAY
0
0
Note : Range 0 to 99 hours. 00 = function disabled.
Press 7 to save and continue.
Display Explanations/comments
P U P Pump Motor Delay menu.
d E L A Y Input the value in seconds.
0
0The left 0 is flashing. Press 9 to increase the value.
Press 8 to go to next digit.
P U P The right 0 is flashing.
dELAY Press 9 to increase the value.
0
0
Press 7 to save and continue.