6.24 Vapour Recovery
The Vapour Recovery function is controlled via a separate Vapour Recovery Controller
(VRC) or third party controlling module i.e. Fafnir, GRVP etc. This menu will indicate
whether vapour recovery is applicable for a selected product. This menu is only visible if
the system detects a VRC board.
6.24.1 KERNEL VERSIONS <= 0.???
Display Explanations/comments
v A P o r Vapour Recovery menu (only if VRC board detected).
HoSE
X
Press 8 to increase the value for X to select hose r/1 (hose
r 0 1 on the right side (side A) of the dispenser).
v A P o r Select position on the VRC system:-
HoSE X Press 9 to increase the value to:-
10
0 = off (no vapour recovery support)
1 = VRC channel 1
2 = VRC channel 2
3 = VRC channel 3
Press 7 to go to next product. Repeat process for each product.
Press 7 to go to next setting.
Display Explanations/comments
v A P o r Vapour Recovery menu (only if VRC board is detected).
Prod
X
Press 8 to select the relevant product number for X.
on
Press 9 to toggle between on (enable) and off (disable).
Press 7 to go to next product. Repeat process for each product.
Press 7 to go to next setting.