WWC T1 Set Up & Maintenance Manual Inspection Functions
Document Ref 905675-001 Rev 2 Page 11-3
11.2 General
In the Inspection Functions menu, the parameters for certain functions have default values
or are disabled. Applications can overrule the default settings - refer to the appropriate
Release Notes for further information.
Note : Menus displayed will depend on the selected application.
11.3 Delivery Mode
Set the required Delivery Mode:-
0 = Standalone Mode
1 = Console Cash
11.4 Traffic Lights
Same functionality as described in detail in section 2.5.2. (for kernel versions <= 01.07)
11.5 Idle Display Control
Set the information to be displayed when the dispenser is idle:-
0 = Last Delivery is displayed
1 = When the filling is cashed, the volume and amount displays show zero
2 When the filling is cashed, all displays show zero
3 to 9 = Reserved for future implementations
11.6 Satellite Control
High speed and very high speed diesel dispensers can have a slave/satellite nozzle on each
side. Select the nozzle at which a filling can be started:-
0 = Satellite Function disabled
1 = Filling using Master nozzle only
2 = Filling using Satellite/Slave nozzle only
3 = Filling using Master or Slave/Satellite nozzle
4 to 9 = Reserved for future implementations