WWC T1 Set Up & Maintenance Manual Maintenance Modes
Document Ref 905675-001 Rev 2 Page 6-19
6.21 Test Delivery
During a test delivery, certain calculator functions can be tested and/or calibrated. If
enabled, a test delivery message will appear on the unit price display. The exact message
will depend on which test is enabled.
Issue B
(CONT.)
Display Explanations/comments
tESt Test Delivery menu.
dEL I v Press 9 to toggle between yes (enable test delivery) and no
no
(disabled).
Select yes to continue.
H I d E Pulser Hide menu.
4
If enabled, the current hide value will be displayed in the amount
YES
window and the unit price display will alternate between the
actual unit price and Hide. Kernel versions 03.16 and above only.
Press 9 to toggle between yes (enable) and no (disable).
Press 7 to save and continue.
r A t E Max Flow Rate menu.
H I G H If enabled, this allows a max. flow rate check per meter by over-
no
riding the default max flow rate of 88 l/min. Two meters per side
can be changed. Very high speed flow rates can be changed for
the second volume only.
Press 9 to toggle between yes (enable) and no (disable).
Select yes to continue.
H I G H Change the max flow rate value for meter 1 on the right side
v o L U 1 (side A):-
r88
Press 9 to change this value.
Press 7 to save and continue.
H I G H Change the max flow rate value for meter 2 on the right side
v o L U 2 (side A):-
r88
Press 9 to change this value.
Press 7 to save and continue.
H I G H Change the max flow rate value for meter 1 on the left side
v o L U 1 (side B):-
L88
Press 9 to change this value.
Press 7 to save and continue.
H I G H Change the max flow rate value for meter 2 on the left side
v o L U 2 (side B):-
L88
Press 9 to change this value.