WWC T1 Set Up & Maintenance Manual LPG Set Up
Document Ref 905675-001 Rev 2 Page 3-3
•N = No nozzle switch present.
The dispenser is activated by pressing the Deadmans Button. A delay timer is
fitted (refer to section 3.1.3) to allow the customer to temporarily release the
Deadmans Button without ending the delivery. When the delay period has elapsed,
the delivery is ended and the transaction data is transmitted to the site controller.
•Y = Nozzle switch is present.
The dispenser is activated by lifting the nozzle. Pressing the Deadmans Button
prior to lifting the nozzle has no effect. The delay timer (refer to section 3.1.3)
is used to end the delivery but the transaction data is not transmitted to the site
controller until the nozzle is replaced (this is intended to prevent a “drive-away”
situation with the nozzle attached to the vehicle).
Refer to section 6.8 for programming information.
3.1.3 LPG DELAY TIMER MENU
This delay timer is designed to allow the customer to accidentally release the
Deadmans Button during filling without ending the delivery.
Default value = 5 seconds
Set the value (0 to 29 seconds) for the time between releasing the Deadmans
Button and the end of the filling:-
•0 = End the delivery immediately upon release of the Deadmans Button
•1 to 29 = End the delivery after the time-out period of x seconds has elapsed.
Data is transmitted to the site controller according to the LPG Nozzle flag.
Refer to section 6.8 for programming information.
3.1.4 LPG MOTOR OFF TIMER MENU
To prevent the rapid switching on/off of the motor by the press and release of
the Deadmans Button, this function
sets an extra delay upon release of the
Deadmans Button.
Default value = 3 seconds
Set the value (0 to 5 seconds) to the minimum length of time for the motor to be
switched off:-
•0 = Keeps the motor running during the entire delivery, from lifting the nozzle
until the nozzle is replaced, preset total reached or error detected.
•1 to 5 = Will not re-start the motor until the time-out period has elapsed.
Refer to section 6.8 for programming information.
Issue A
LPG
dELAY
05
LPG
oFF
3