WWC T1 Set Up & Maintenance Manual Inspection Functions
Document Ref 905675-001 Rev 2 Page 11-5
11.11 Maximum Time a Filling can be Suspended
Within this set time, a filling must be started (released via Payment Terminal) or continued
at a slave/satellite dispenser. If this time is exceeded, the filling is ended and the dispenser
must be released before it can be used again. Set the time limit:-
0000 = Function disabled
0959 = Max time (9 minutes and 59 seconds)
0100 = Default value (1 minute)
11.12 Timer for Display TImeout
This menu is only visible when the Combined Hose Product Display setting is activated in
the Set Up menu. Set the time:-
0001 = Min time (1 second)
0950 = Max time (9 minutes and 50 seconds)
0100 = Default value (1 minute)
11.13 Delivery Fraud Timer
Set the time for a fraudulent delivery to last before a fraud error is registered:-
0005 = Min time (5 seconds)
0959 = Max time (9 minutes and 59 seconds)
0100 = Default value (1 minute)
11.14 Software Versions
This menu displays the software version of the kernel, application, and the various
peripherals connected to the WWC. Refer to section 2.5.3 for kernel versions.
Issue A
Press 9 to change the value.
Press 8 to select another digit.
Note : 10 second increments.
Display Explanations/comments
S o F t Software Version menu.
v E r S Peripherals connected to the WWC will be detected.
Press 8 to enter this menu.
dEL I v dEL I v
SUSP r SUSP L
XXXX XXXX
cH Pro
dISPL
0100
dEL I v dEL I v
Frd r Frd L
XXXX XXXX
(Cont.)