Page 5-2 Document Ref 905675-001 Rev 2
Set Up Modes WWC T1 Set Up & Maintenance Manual
5 SET UP MODE
5.1 General
The set up of the calculator is a set of procedures which initialise the system according to
the requirements of the dispenser itself and also individual customer requests. There are
two main sequences to be followed:-
Set Up
This defines the dispenser including country specific and Weights & Measures (W&M)
related issues (Set Up mode)
Configuration
This defines the customer related functionality (Maintenance mode and Application mode)
If applicable, the operator will be prompted by the calculator to enter the mandatory
information (the set up code) before entering Operational mode. Additional optional
parameters can be set later via separate menus: in Maintenance mode (key 5), Inspection
mode (key 6) or Application mode (key 3).
5.2 Start Ups
At power up, the WWC can start up in three different ways according to the positions of
jumpers W201 and W202:-
Cold start : Jumper W201 and W202 are both OFF (refer to section 5.2.1)
A set up sequence is automatically started. A complete reconfiguration of the dispenser is
mandatory. Note : This includes country specific and W&M related parameters.
Warm start : Jumper W201 is ON and W202 is OFF (refer to section 5.2.2)
This is the normal start-up after power-down. All data is restored from previous sessions.
If there are no problems detected during power-on self tests, the calculator is immediately
ready for operation.
Service start : Jumper W201 and W202 are both ON (refer to section 5.2.3)
Only the configuration data from previous sessions is used. All other data (totals and
current status of the calculator) are cleared. This option allows the service engineer to
start with a “clean” calculator without having to run through all configuration steps.
5.2.1 COLD START
When jumper W201 and W202 are both OFF, the calculator is forced into a set
up sequence and ‘SEtUP’ is displayed. All memory, including country specific
and W&M related parameters, is cleared.
Issue A
Display Explanations/comments
Set Up menu (first display after power up).
SE t UP
Set Up is flashing.
Press 7 to continue.