Page 3-2 Document Ref 905675-001 Rev 2
LPG Set Up WWC T1 Set Up & Maintenance Manual
3 LPG SET UP
This section will cover the the hydraulic situation and the functional operation for LPG dispensers:-
LPG Functionality (refer to section 3.1)
LPG Hydraulic Functions (refer to section 3.2)
Functionality with Nozzle Switch (refer to section 3.3)
Functionality without Nozzle Switch (refer to section 3.4)
3.1 LPG Functionality
LPG functionality is supported by selecting set up 60 or 61 on the WWC:-
Set Up 60 - original LPG set up for use with an extra HOM module for the LPG hydraulic
group. Maximum functionality is LPG + 4 additional products.
Set Up 61 - added as a low-end solution for LPG dispensers based on the use of the
mainboard only. Maximum functionality is LPG + 2 additional products using the I/O
board.
Within the LPG set up are the following menus:-
LPG Pulse menu (refer to section 3.1.1)
LPG Nozzle menu (refer to section 3.1.2)
LPG Delay Timer menu (refer to section 3.1.3)
LPG Motor Off Timer menu (refer to section 3.1.4)
3.1.1 LPG PULSE MENU
This menu is read-only and can only be changed within the start-up menu.
Default value =
2cl
Set the value according to the pulser and volume meter fitted:-
1cl for Satam 700 Piston Meter
2cl for Schwelm and Nuouvo Pignone Meters without gearboxes
Refer to section 6.8 for programming information.
3.1.2 LPG NOZZLE FLAG MENU
This menu toggle identifies if the dispenser is equipped with a nozzle switch.
Default value = Y
Set the value according to whether the dispenser is fitted with a nozzle switch:-
Issue A
LPG
PULSe
1
cl
LPG
nOZZLE
yes