6.9 Thermal Protection Reset
When the thermal protection of a motor is tripped, the calculator will not allow the motor
to re-start without user intervention either via this menu or via an optional button.
6.9.1 KERNEL VERSIONS > 01.07
6.9.2 KERNEL VERSIONS <= 01.07
With kernel versions equal to or less than 01.07 the diagnostic information is
displayed in a different layout.
Issue A
Display Explanations/comments
t P r o t Thermal Protection Reset menu.
PUP
1
Once a motor is tripped, this menu must be entered to re-start
oFF
the motor for the associated product.
Press 8 to increase the value until the relevant motor number is
displayed.
Press 9 to toggle between on (reset) and off (motor disabled).
Note : When Thermal Protection is set to off, the associated
product will be unavailable.
Refer to Hydraulic Set Ups for motor numbers.
Press 7 to save and continue.
Display Explanations/comments
t P r o t Thermal Protection Reset menu.
Prod
1
Once a motor is tripped, this menu must be entered to re-start
on
the motor for the associated product.
Press 8 to increase the value until the relevant motor number is
displayed.
Press 9 to toggle between on (reset) and off (motor disabled).
Note : When Thermal Protection is set to off, the associated
product will be unavailable.
Refer to Hydraulic Set Ups for motor numbers.
Press 7 to save and continue.