EasyManua.ls Logo

Tokheim WWC T1 - Kernel Versions <= 01.07

Tokheim WWC T1
158 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WWC T1 Set Up & Maintenance Manual Maintenance Modes
Document Ref 905675-001 Rev 2 Page 6-7
With kernel versions equal or less than 01.07 the diagnostic information is displayed in a
different layout. For a detailed description, refer to Appendix C.
6.5.2 KERNEL VERSIONS <= 01.07
Display Explanations/comments
E r r o r Error Log menu.
LoG
Press 8 to enter this menu.
E r r o r If there are no errors logged in the database, no will be displayed.
Press 0 to return to Error Log menu.
no
Er
XX
If errors are logged in the database, the first error is displayed
see
(sorted by component). For detailed error codes, refer to Appendix.
nn
s = dispenser side (right/side A or left/side B)
ee = error type number
nn = error counter
XX = error code (see below)
Error code:-
AP = Application error (to be defined)
GE = Kernel error
Hc = HCM error
Pu = HOM error
cS = CSD error
So = SOM error
UA = UAM error
Ec = ECVR error
nb = Nozzle Bus error
Press 8 to go the next error for the same component.
Press 0 to return to Technicians menu.
Press 7 to go to the next component (if applicable).
Press 7 to continue.
E v E n t Event Log menu.
LoG
Press 8 to enter this menu (same as Error Log menu).
Press 0 to return the previous menu.
Press 7 to continue.
r E S E t Reset Error Log menu.
Error Press 9 to toggle between yes and no.
no
Select yes and press 7 to continue.
Issue A

Table of Contents