Page 6-10 Document Ref 905675-001 Rev 2
Maintenance Modes WWC T1 Set Up & Maintenance Manual
Issue A
6.8 LPG Functionality
This function enables the selection of a nozzle switch or Deadmans button and the ability
to set a delay timer for stopping the motor after the LPG button is released accidentally.
Note : This menu is only visible if an LPG setup is selected.
Display Explanations/comments
L P G LPG menu (LPG set ups only).
Press 8 to enter the LPG functions.
LPG LPG Pulse Menu.
PULSE Note : This menu is read-only and can only be changed after a
2cl cold start.
Press 7 to continue.
Press 0 to return to LPG menu.
L P G Nozzle Switch menu.
noZZLE Press 9 to toggle between yes (if nozzle switch present) and no.
no
Press 7 to save and continue.
Press 0 to return to LPG menu.
L P G LPG Motor Off Delay menu.
o F F Set the value for the motor off delay (0 to 5 seconds).
3
Default 3 is flashing. Press 9 to increase this value (max. 5).
Press 7 to save and continue.
Press 0 to return to LPG menu.
LPG LPG Delay menu.
d E L A Y Set the value of the LPG delay timer i.e. time between release of
0
5 Deadmans button and the end of the filling (0 to 29 seconds).
The left 0 is flashing. Press 9 to increase this value.
Press 8 to select right hand digit. Press 9 to increase this value.
Press 7 to save and continue.
Press 0 to return to LPG menu.