Tokheim WWC T1 - 6.10 Leak Detection Functionality

Tokheim WWC T1
158 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 6-12 Document Ref 905675-001 Rev 2
Maintenance Modes WWC T1 Set Up & Maintenance Manual
6.10 Leak Detection Functionality
This menu is displayed when the hose is activated and ready for use.
6.10.1 VAPOUR LEAK DETECTION (FRANCE ONLY)
When a leak is detected, the calculator will not allow the motor to re-start without
user intervention via this menu. The Flow Leak menu changes into:-
Issue A
6.10.2 FLOW PROTECTION RESET (AFM LEAK DETECTION)
When a flow protection error is detected, the calculator will not allow the motor
to re-start without user intervention via this menu. The Flow Leak menu changes
into:-
Display Explanations/comments
F L P r o t Flow Protection menu.
Ho
r1
The associated product must be reset to on to allow the motor to
oFF
re-start.
Press 8 to increase the product number (right then left).
Press 9 to toggle between on and off .
Press 7 to save and continue.
Display Explanations/comments
F L L E A Fuel Leak menu.
Ho
r1
The first product is displayed.
on X
Press 8 to increase the product number (right then left).
Press 9 to toggle between on and off.
X refers to the number of leak defaults detected (0,1 or 2).
Note : For kernel versions <3.13, X is not present.
Press 7 to save and continue.
Display Explanations/comments
F r L E A French Vapour Leak menu.
Ho
r1
The associated product must be reset to on to allow the motor to
oFF
re-start.
Press 8 to increase the product number (right then left).
Press 9 to toggle between on and off .
Press 7 to save and continue.