Page 5-6 Document Ref 905675-001 Rev 2
Set Up Modes WWC T1 Set Up & Maintenance Manual
Issue B
(CONT.)
Explanations/comments
GALLon Gallon menu.
Default no is flashing. Press 9 to toggle to yes to change the
no
volume measurement to gallons.
Press 7 to save and continue.
GALLon If Gallon is selected the Gallon type menu is displayed.
Default US is flashing. Press 9 to toggle to InnP.
US
Press 7 to save and continue.
d I S P Set Up Codes menu.
SE t UP
Note : Set up codes are predefined - refer to the Appendix.
52
Press 9 to scroll through available set up codes.
Note : If no set up is selected an error message will be displayed.
Press 7 to save and continue.
n b o F Number of HS Motors menu (set up 53 only).
m o t o r Default 2 is flashing. Press 9 to toggle to 1.
2
Press 7 to save and continue.
L P G LPG Pulse Meter menu (LPG set ups only)
PULSE
Default value 2 is flashing. Press 9 to toggle to 1.
2
cL
Note : Refer to section 3.1 for more on LPG functionality.
Press 7 to save and continue.
HoSE
Maximim Number of Hoses menu.
Lr
Set the value for the maximum number of hoses per side including
X
X
satellite/slave hoses (max. 6 hoses per side).
Set maximum number of hoses for the right side (side A):-
The right X is flashing. Press 9 to increase the value.
Press 8 to set values for opposite side.
HoSE
Set maximum number of hoses for the left side (side B):-
Lr
The left X is flashing. Press 9 to increase the value.
X
X
Press 7 to save and continue.