ERROR CODE AND TROUBLESHOOTING
6 - 95
(1) Set the values of “Image quality closed-loop control / Contrast voltage (08-556)” and “Image
quality closed-loop control / Laser power (08-557)” to “0” (Invalid).
(2) Perform “Enforced performing of image quality open-loop control (05-394)”.
(3) Output the image quality control test pattern (04-270) more than one time and the list print
([9][START]) in the adjustment mode (05), and then check if the image is normal.
|
|
|
|
|
|
|
|
|
|
Normal Abnormal
Abnormal image:
Blank print, Solid print, White banding, Color banding, White spots, Poor
transfer, Uneven image density, Faded image (low density), Uneven light
distribution, Blotched image.
* Blank print: including when one of the YMCK colors is not printed.
Correct the abnormal image.
Proceed to step (5).
(4) Replace the image quality sensor or the LGC board.
(5) Set the values of “Image quality closed-loop control / Contrast voltage (08-556)” and “Image
quality closed-loop control / Laser power (08-557)” to “1” (Valid).
(6) Perform “Automatic initialization of image quality control (05-396)” and make sure it is
completed normally. (Error [CE10], [CE20] and [CE40] do not appear.) Then perform
“Automatic gamma adjustment” (Chapter 3.7.1 and 3.8.1).
| When an error occurs:
Check and correct it accordingly.
(7) Reset all of the values in the codes “Abnormality detection count (Y/M/C/K) Display/0 clearing
(08-573 to 08-576)”.