Vertical Summit80 & Summit800
Feature Description and Operation Manual Issue 1.2
309
4. OUTSIDE (CO/IP) LINES
4.1 Auto Fault Detection and Recovery
Description
If the system detects a Line fault on a PRI Line or SIP Trunk, the Line/Trunk is placed in an Out-
Of-Service state and temporarily placed it in the unused Line group. Upon recovery the system
will automatically return the Line to in-service. Co line fault information is provided to NMS if it is
connected.
Operation
System
Operation of Fault Detection and Recovery is automatic.
Conditions
1. The ―UnusedLine Group contains Lines that are not used or are temporally blocked.
2. This feature is only available for PRI Lines and SIP trunks.
Programming
Keyset Admin.
CO/IP
System Data
CO/IP Line Group (PGM 141-Button
DCOB Fault Notify (PGM163-Button 6)
SIP Registration Fault Notify (PGM163-Button 7)
Web Admin.
CO LINE DATA
Common Attributes CO/IP Group
System Data
Alarm Attributes DCOB Fault Notify, SIP Registration
Fault Notify
Related Features
Outside Line Groups
Hardware

Table of Contents