Feature Description and Operation Manual Issue 1.2
314
4.6 Dial Pulse Signaling
Description
An analog CO Line can be configured to send dial pulse signals to the central office. If
programmed as a pulse CO line, the system will send open loop pulses at 10 pps with the
assigned break/make ratio.
Operation
System
Operation of this feature is automatic when programmed.
Conditions
1. The break/make ratio is system programmable as 60/40 or 66/33.
2. You can change the signaling from pulse to DTMF by dialing ‗*‘ while on a Line
assigned for pulse signaling.
Programming
Keyset Admin.
CO/IP
CO Line Signal Type (PGM 141-Button 5)
SYSTEM
Pulse Dial (Break/Make) Ratio (PGM 176)
Pause Timer (PGM 181-Button 10)
Web Admin.
CO LINE DATA
Common Attributes Analog AttributesCO Line Signal
SYSTEM DATA
Pulse Dial (Break/Make) Ratio
System Timers Pause Timer
Related Features
Dial Pulse to Tone Switchover
DTMF Signal Sending
Hardware

Table of Contents