OM EZ17 us 1.0 * ez17w700.fm 7-3
7
Check the antifreeze at temperatures below 4 °C (39 °F).
Option
Check the load hook, joint rod, lifting eyes 7-51
Check the hydraulic quickhitch (Easy Lock) for damage --
Check the Powertilt for damage --
Weekly maintenance (every 50 service hours) (operator) Page
Lubricate the machine according to the lubrication plan 7-6
Clean the lights/light system, signaling system, acoustic warning system --
Check V-belt condition and tension 7-40, 7-41
Option
Actuate Powertilt swivel device in final position for 1 minute
2
--
All steps for previous maintenance intervals --
1. Air filter replacement according to the dirt indicator, every 1000 s/h or once a year at the latest. (Replace after 50 s/h when in extensive use in environments
with acidic air, such as acid production facilities, steel and aluminium mills, chemical plants and other nonferrous-metal plants, independently of the dirt indi-
cator)
2. Rinse the system to remove dirt. Repeat the procedure in the opposite flow direction.
Daily maintenance (operator)