4-30 OM EZ17 us 1.0 * ez17i400.fm
4
4.5 Starting and stopping the engine
Preparations for starting the engine
WARNING
Accident hazard due to uncontrollable machine operation!
Uncontrollable operation can cause serious injuries or death.
Only operate the machine from the seat with the seat belt fastened.
Set the throttle to the medium position if the engine is cold.
The starter cannot be actuated if the engine is already running (start
repeat interlock).
Do not run the starter for more than 10 seconds.
Wait about 1 minute so the battery can recover and the starter does not
overheat before trying again.
Information
Ensure that there is sufficient ventilation before operating the machine in
enclosed areas.
Information
All controls must be within easy reach. You must be able to move the
travel levers to their limit positions.
Starter
Fig. 69
0
1
2
3
P
Position Function
P Park position Not assigned
0 Stop position Insert or remove the starting key
1 Travel position All electric functions are enabled
2 Preheats the engine Preheater active
3 Starts the engine Starter is actuated

Table of Contents