OM EZ17 us 1.0 * ez17w700.fm 7-29
7
Bleeding the fuel system
Bleed the fuel system in the following cases:
If the fuel filter, prefilter or the fuel lines are removed and fitted back on
again.
If the fuel tank is run empty.
If the machine is put into operation after having been decommissioned
for more than 30 days.
Bleed the fuel system as follows:
1. Raise the control lever base.
2. Remove the starting key and carry it with you.
3. Fill up and close the fuel tank.
4. Turn the starting key to the first position.
5. Wait about 5 minutes while the fuel system bleeds itself automatically.
6. Start the engine.
If the engine runs smoothly for a while and then stops, or if it does not run
smoothly:
1. Stop the engine.
2. Raise the control lever base.
3. Remove the starting key and carry it with you.
4. Bleed the fuel system again as described above.
5. Check for leaks after starting the engine.
6. Have a Wacker Neuson service center perform a check if necessary.
Checking the water separator
Water separator
Empty the water separator if the red indicator ring A rises to position B.
Fig. 193
A
B

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson EZ17 and is the answer not in the manual?

Wacker Neuson EZ17 Specifications

General IconGeneral
BrandWacker Neuson
ModelEZ17
CategoryExcavators
LanguageEnglish

Related product manuals