4-10 OM EZ17 us 1.0 * ez17i400.fm
4
Control lever base
Raise the control lever base 20 after stopping the engine.
Control lever base raised:
All hydraulic functions are locked.
The engine will not start unless the control lever base is raised.
Control lever base lowered:
All hydraulic functions are active.
The engine cannot be started.
Functional check of control lever base
Perform a functional check of the control lever base every time before you
start the machine.
1. Start the machine.
2. Lower the control lever base.
3. Travel on open terrain.
4. Secure the danger zone.
5. Stop the machine.
6. Raise the control lever base.
7. Move all control levers and pedals in all directions.
The selected elements must not move.
Work may be performed with the machine.
8. The selected elements move:
Stop operation immediately.
Contact a Wacker Neuson service center and have the malfunction
rectified.