Edge [ii] Controller Operation Manual
SECTION 7 UNIT STATUS
OMM-139_E 8/25/2020 Technical Support (800) 526-0288 Mon-Fri, 8 am - 5 pm EST Page 180 of 196
The Event Details screen contains the following parameters:
Date
Outlet temperature
Flame strength
Time
Inlet temperature
O2 level
Event Code
Air temperature
O2 Trim state
Valve position
Exhaust temperature
7.9 Plant Event History
The Plant Event History screen is displayed in the round-robin queue on BST Manager units
only. It is similar to the unit Event History screen, in that it displays a list of events, however in
this screen, the events can come from any unit in the cascade, with the Unit ID column
indicating which unit the event occurred on, or Plant for plant level events such as
communication fault with BAS.
The Plant Event History screen displays the same layout, number of event and color coding as
the Unit Event History screen. However, plant-level events do not have additional details.
Figure 7.9: Plant Event History

Table of Contents