4. Duplex filter
For data about the duplex filter (1, Fig. 2) refer to the Operation Manual 72181,
paragraph 2.
4.1 Clogged Filter Element Replace
1) Close the ball valve (6).
2) Remove the cover from the rail unit.
3) Move the lever (5) to select the clean filter element.
4) Remove the three nuts (3) on the applicable filter chamber (4), then remove the
cover (2).
5) Replace the clogged filter element.
Note: As an alternative, you can clean the clogged filter element, refer to
paragraph 4.2.
6) Attach the cover (2) to the filter chamber (4) with the three nuts (3).
7) Clean the external surface of the duplex filter (1).
8) Install the cover you removed before to the rail unit.
9) Open the ball valve (6).
4.2 Filter Element Clean
For data about the procedure to clean the filter element, refer to the documentation of
the filter element manufacturer.