Maintenance
03801/A1
Winterthur Gas & Diesel Ltd.
9/ 11
Group Component Procedure Intervals and Service
Life (operation hours)
66061 Scavenge air
cooler
Clean the scavenge air cooler (air side) during
operation each week. Later if np (pressure
decrease through the SAC) increases
compared to the shop test value at the same
engine load (refer to the Operation Manual
66061)
As necessary
Do a check of the condensate collector
through the sight glass (refer to the Operation
Manual 83451)
Daily
Make sure that the condensate collector is not
blocked (refer to the Operation Manual
83451)
1500 to 3000
Check scavenge air cooler sealing Quarterly
Bleed Daily
Remove the scavenge air cooler for overhaul As necessary
67081 Water separator
scavenge air
Do a check of the condensate collector
through the sight glass (refer to the Operating
Manual 83451)
Daily
Make sure that the condensate collector is not
blocked (refer to the Operating Manual
83451)
1500 to 3000
Do a check of the the water separator
elements (if necessary clean them)
1500 to 3000
Remove the water separator for overhaul As necessary
7
72181 Cylinder
Lubricating
pump
Remanufacture cylinder lubricating pump or
overhaul on board
45000
Filter
replacement
Replace the filter element upstream of the the
cylinder lubricating system
As necessary
Estimated service life: Cylinder lubricating
pump
30000
8
81351
Exhaust Waste
Gate (LLT)
General inspection. During a longer operation
period at low engine load, manually open the
butterfly valve a minimum of one time each
week (refer to the Operation Manual 81351)
In accordance with the
instructions of the valve
manufacturer
Servo oil service
pump (engine
mounted)
Do a check of the flow rate and maximum
pressure
30000
Starting air
pipes on and
before the
engine
Drain (remove water) Before and after each
maneuvering period
Inspection and Overhaul Intervals (Guidelines)
2020