60H5E11
Power unit
POWR
NOTE:
Screw-in the flywheel puller set bolt until the
flywheel magnet comes off completely.
3. Remove the Woodruff key.
Removing the electrical components
1. Remove the stator assembly.
2. Remove the pulser coil assembly.
60H50140
3. Remove the starter motor.
60h50150
Flywheel holder : 90890-06522
Flywheel puller : 90890-06521
5-15
Removing the flywheel magnet
1. Remove the nut on the flywheel magnet.
60H50110
: 30 mm
Apply force in the direction of the arrows
shown. While working, take precautions
against the slipping off of the flywheel
holder.
2. Remove the flywheel magnet.
60H50120
• Screw-in the flywheel puller set bolts
evenly to the full extent.
• Make sure that the puller plate is set in
parallel with the flywheel magnet.