9 Utility Functions
9-12
(4) Related Parameters
The following parameters set the program JOG operation pattern. Do not change the settings while the pro-
gram JOG operation is being executed.
Pn530
Program JOG Operation Related Switch   
Classification
Setting Range Setting Unit Factory Setting When Enabled
0000 to 0005 0000 Immediately Setup
Pn531
Program JOG Movement Distance   
Classification
Setting Range Setting Unit Factory Setting When Enabled
1 to 1073741824 1 reference unit 32768 Immediately Setup
Pn533
Program JOG Movement Speed   
Classification
Setting Range Setting Unit Factory Setting When Enabled
1 to 10000
1 min
-1
500 Immediately Setup
Pn534
Program JOG Acceleration/Deceleration Time   
Classification
Setting Range Setting Unit Factory Setting When Enabled
2 to 10000 1 ms 100 Immediately Setup
Pn535
Program JOG Waiting Time   
Classification
Setting Range Setting Unit Factory Setting When Enabled
0 to 10000 1 ms 100 Immediately Setup
Pn536
Number of Times of Program JOG Movement   
Classification
Setting Range Setting Unit Factory Setting When Enabled
0 to 1000 1 time 1 Immediately Setup
Speed
Position
Torque
Speed
Position
Torque
Speed
Position
Torque
Speed
Position
Torque
Speed
Position
Torque
Speed
Position
Torque

Table of Contents