11 Appendix
11.2.1 List of Parameters
11-14
Pn590
2
Input Signal Selection
(P-OT Signal Assignment)
0000 to
2007
– 0000 After restart Setup − –
Pn591
2
Input Signal Selection
(N-OT Signal Assignment)
0000 to
2007
– 0000 After restart Setup − –
(cont’d)
Parameter
No.
Size Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification Profile
Reference
Section
4th 3rd 2nd 1st
digit digit digit digit
n.
P-OT Signal Pin Number Assignment
Reference
Section
0 Selects sequence input signal /SI-0.
7.3.2
1 Selects sequence input signal /SI-1.
2 Selects sequence input signal /SI-2.
3 Selects sequence input signal /SI-3.
4 Selects sequence input signal /SI-4.
5 Selects sequence input signal /SI-5.
6 Selects sequence input signal /SI-6.
7 Selects sequence input signal /SI-7.
Reserved (Do not change.)
Reserved (Do not change.)
P-OT Signal Assignment Selection
Reference
Section
0 P-OT signal assignment disabled. [factory setting]
7.3.2
1 P-OT signal assigned. Positive drive is enabled when the signal is low.
2 P-OT signal assigned. Positive drive is enabled when the signal is high.
4th 3rd 2nd 1st
digit digit digit digit
n.
N-OT Signal Pin Number Assignment
Reference
Section
0 Selects sequence input signal /SI-0.
7.3.2
1 Selects sequence input signal /SI-1.
2 Selects sequence input signal /SI-2.
3 Selects sequence input signal /SI-3.
4 Selects sequence input signal /SI-4.
5 Selects sequence input signal /SI-5.
6 Selects sequence input signal /SI-6.
7 Selects sequence input signal /SI-7.
Reserved (Do not change.)
Reserved (Do not change.)
N-OT Signal Assignment Selection
Reference
Section
0 N-OT signal assignment disabled. [factory setting]
7.3.2
1 N-OT signal assigned. Reverse drive is enabled when the signal is low.
2 N-OT signal assigned. Reverse drive is enabled when the signal is high.