11.7 E: Motor Parameters
246 YASKAWA SIEPYEULA5001C LA500 Technical Manual
11.7 E: Motor Parameters
E1: V/f Pattern for Motor 1
No.
(Hex.)
Name Description
Default
(Range)
Ref.
E1-01
(0300)
Input AC Supply Voltage
Sets the drive input voltage.
NOTICE: Damage to Equipment. Set E1-01 [Input AC Supply
Voltage] to align with the drive input voltage (not motor
voltage). If this parameter is incorrect, the protective functions
of the drive will not operate correctly and it can cause damage
to the drive.
400 V: 400 V
(400 V Class: 310 - 510
V)
299
E1-04
(0303)
Maximum Output
Frequency
Sets the maximum output frequency for the V/f pattern.
Determined by A1-02
(10.0 - 120.0 Hz)
299
E1-05
(0304)
Maximum Output
Voltage
Sets the maximum output voltage for the V/f pattern.
400 V Class: 380.0 V
(400 V Class: 0.0 - 510.0
V)
299
E1-06
(0305)
Base Frequency
Sets the base frequency for the V/f pattern.
Determined by A1-02
(0.0 - 120.0 Hz)
299
E1-07
(0306)
Middle Output
Frequency
Sets a middle output frequency for the V/f pattern.
Determined by A1-02
(0.0 - 120.0 Hz)
299
E1-08
(0307)
Middle Output
Frequency Voltage
Sets a middle output voltage for the V/f pattern.
Determined by A1-02
and o2-04
(400 V Class: 0.0 - 510.0
V)
300
E1-09
(0308)
Minimum Output
Frequency
Sets the minimum output frequency for the V/f pattern.
Determined by A1-02
(0.0 - 120.0 Hz)
300
E1-10
(0309)
Minimum Output
Voltage
Sets the minimum output voltage for the V/f pattern.
Determined by o2-04
(400 V Class: 0.0 - 510.0
V)
300
E1-11
(030A)
Expert
Middle Output
Frequency 2
Sets a middle output frequency for the V/f pattern.
0.0 Hz
(0.0 - 120.0 Hz)
300
E1-12
(030B)
Expert
Middle Output
Frequency Voltage 2
Sets a middle point voltage for the V/f pattern.
0.0 V
(400 V Class: 0.0 - 510.0
V)
300
E1-13
(030C)
Expert
Base Voltage
Sets the base voltage for the V/f pattern.
0.0 V
(400 V Class: 0.0 - 510.0
V)
300
E2: Motor Parameters
No.
(Hex.)
Name Description
Default
(Range)
Ref.
E2-01
(030E)
Motor Rated Current
(FLA)
Sets the motor rated current in amps.
Determined by o2-04
(10% to 200% of the
drive rated current)
301
E2-02
(030F)
Motor Rated Slip
Sets motor rated slip.
Determined by o2-04
(0.00 - 20.00 Hz)
301
E2-03
(0310)
Motor No-Load Current
Sets the no-load current for the motor in amps when operating at the rated frequency
and the no-load voltage.
Determined by o2-04
(0 to E2-01)
301
E2-04
(0311)
Motor Pole Count
Sets the number of motor poles.
4
(2 - 48)
301
E2-05
(0312)
Motor Line-to-Line
Resistance
Sets the line-to-line resistance for the motor stator windings.
Determined by o2-04
(0.000 - 65.000 Ω)
301
E2-06
(0313)
Motor Leakage
Inductance
Sets the voltage drop from motor leakage inductance when the motor is operating at the
rated frequency and rated current. This value is a percentage of Motor Rated Voltage.
Determined by o2-04
(0.0 - 60.0%)
302
E2-07
(0314)
Motor Saturation
Coefficient 1
Sets the motor iron-core saturation coefficient at 50% of the magnetic flux.
0.50
(0.00 - 0.50)
302
E2-08
(0315)
Motor Saturation
Coefficient 2
Sets the motor iron-core saturation coefficient at 75% of the magnetic flux.
0.75
(E2-07 - 0.75)
302
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV

Table of Contents

Other manuals for YASKAWA LA500

Related product manuals